SEARCH THE RESOURCE LIBRARY
WATCH NOW
REGISTER FOR UPCOMING TRAINING
LEARN MORE BUY A SUBSCRIPTIONVIEW/MANAGE ENROLLMENT INFOGO TO THE LEARNING CENTER
VIEW YOUR PURCHASED TRAINING
Need an Accredited service center?Find a service center that has proven they repair electric motors in accordance with ANSI/EASA's AR100.
VIEW THE LISTLEARN MORE ABOUT THE PROGRAM
DOWNLOAD ACCREDITATION CHECKLISTACCREDITED? VIEW YOUR RECORDS
Reserve Your Room & Register
It's not too early to reserve your room at EASA's official 2024 hotel. Don't wait to save your place at the 2024 Convention & Solutions Expo.
RESERVE ROOM REGISTER TO ATTEND
Engage locallyEASA's international membership is divided into 10 Regions that are made up of 32 Chapters.
EXPLORE CHAPTERS & EVENTS NEAR YOU
CHAPTER OFFICER RESOURCES
SEARCH THE ONLINE STORE
CUSTOM BRANDED PRODUCTSDOWNLOADS YOU HAVE PURCHASEDVIEW YOUR PURCHASED TRAININGVIEW CONVENTION RECORDINGS
Unless great care is taken, pulling magnet wire from a motor stator often bends or splays the lamination’s end teeth. Bent teeth, or teeth that have been splayed outward at the ends of the core stack, will likely compromise the quality of the repair job. Therefore, we have designed and implemented the use of disc clamps to hold the stator tooth tips in place while pulling magnet wire from the slots. The clamping fixtures described in the photos have helped ensure that we avoid damaging the stator teeth during the stripping process.
A no ser que se tenga mucho cuidado, tirar del alambre magneto al desmantelar el estator de un motor a menudo deforma o dobla los dientes de las laminaciones. Estos dientes deformados comprometerán la calidad de la reparación y hay estudios que demuestran que este problema puede reducir la eficiencia del motor. Sin embargo, aunque esta reducción puede ser pequeña, genera altos costos y desperdicio de energía.
This article looks at some of the import details for a proper concentric to lap winding conversion. It also shows how using the EASA Technical Manual, EASA's AC Motor Verification & Redesign Software, as well as the EASA AC Redesign manual, can help.
Este artículo analiza algunos de los detalles de importación para una conversión adecuada de devanado concéntrico a devanado por vuelta. También muestra cómo puede ayudar el uso del Manual técnico de EASA, el software de rediseño y verificación de motores de CA de EASA, así como el manual de Rediseño de motores AC de EASA.
This video shows one step in collecting motor winding data: how to measure magnet wire.
This webinar recording shares some of the “best practice” rewind methods used by (and learned from) EASA service centers around the world: connection recognition, best insulating materials, wire choices and tips to save time and effort.
A special discounted collection of 12 webinar recordings focusing on AC motor windings.
Just $60 for EASA members!
With a steady increase in random wound AC motor sizes and the obvious superiority of the form coil winding, one area where we can help improve customers' motor reliability is by redesigning those large random wound motors to accept form coils. Most repairers would agree that machines rated larger than 600 hp (450 kW) should be designed as form coil machines. Likewise, those rated over 2 kV will be much more reliable as form coil machines.
No one wants to rewind a motor using 60 #14 AWG (62- 1.6 mm) wires in hand. With an abundance of niche suppliers of stator laminations, the cost and practicality of converting a random wound motor to form coil are available to nearly all service centers. Replacement laminations can be punched, laser-cut or water-cut, and supplied with very reasonable delivery times.
Con el aumento continuo de los tamaños de los motores CA y la obvia superioridad de los devanados con bobinas preformadas (pletina o solera), un área en la que podemos ayudar a mejorar la confiabilidad de los motores de nuestros clientes es rediseñando estos motores grandes de alambre redondo para que acepten bobinas preformadas. La mayoría de los reparadores estarían de acuerdo en que las máquinas de alambre redondo por arriba de 600 hp (450 kW) deberían rediseñarse con bobinas preformadas. Así mismo, aquellas con tensiones nominales superiores a 2 kV serían más confiables con bobinas de pletina.
Nadie quiere rebobinar un motor con 60 #14 AWG (62- 1.6 mm). Con la abundancia de proveedores especializados en laminaciones de estatores, el costo y la practicidad para convertir motores de alambre redondo a pletina está al alcance de casi todos los centros de servicio. Las laminaciones para reemplazar el núcleo pueden ser troqueladas o cortadas con láser o agua y entregadas en tiempos muy razonables.
An increasing number of manufacturers are using magnetic wedges in their form-wound machines. When a winder fails to replace magnetic wedges in kind, the winding temperature rise can increase by 20°C, and the magnetizing current can increase by 20% or more.
This 40-page booklet provides great advice for obtaining the longest, most efficient and cost-effective operation from general and definite purpose electric motors.
This booklet covers topics such as:
LEARN MORE AND DOWNLOAD MÁS INFORMACIÓN Y DESCARGAR BUY PRINTED COPIES
READ MORE ABOUT THE FEATURES AND BENEFITS
The Effect of Repair/Rewinding on Premium Efficiency/IE3 Motors Tests prove Premium Efficiency/IE3 Motors can be rewound without degrading efficiency.
DOWNLOAD THE FULL RESULTS
Recommended Practice for the Repair of Rotating Electrical Apparatus This is a must-have guide to the repair of rotating electrical machines. Its purpose is to establish recommended practices in each step of the rotating electrical apparatus rewinding and rebuilding processes.
DOWNLOAD - ENGLISH
DESCARGAR - ESPAÑOL
Revised September 2022 The EASA Technical Manual is the association's definitive and most complete publication. It's available FREE to members in an online format. Members can also download PDFs of the entire manual or individual sections.
VIEW & DOWNLOAD